To replace windows in Coral Springs, pick impact products approved for the High Velocity Hurricane Zone, because all of Broward County is HVHZ. Get any HOA approval, then apply for a permit through the city's eTRAKiT portal with the Form 015.1 retrofit packet. Inspections are booked online, and a wind mitigation form documents the finished openings.
Last checked: October 24, 2026 · General guidance. Confirm requirements for your address with the Coral Springs building department.
Inland Coral Springs still follows the High Velocity Hurricane Zone rules
Coral Springs sits about 20 miles northwest of Fort Lauderdale, with the Everglades to the west and the Sawgrass Expressway along its north and west edges. Being inland does not change the window rules.
The 2023 Florida Building Code (8th Edition) defines the High Velocity Hurricane Zone (HVHZ) as Broward and Dade counties. Coral Springs is in Broward, so the HVHZ rules cover every street in the city, from Eagle Trace to Ramblewood.
Local history explains why. The eye of Hurricane Wilma passed directly over Coral Springs in October 2005. It was the strongest storm to hit the city since it was chartered in 1963, and news reports described many roofs badly damaged here. During Irma in 2017, tornado warnings were issued for Coral Springs and some areas lost power for up to a week.
Your house was probably built in the 1980s: what that means for the job
Coral Springs grew as a master-planned city. The Census Bureau's 2024 one-year estimate puts the median year built at 1988. About 79% of homes went up before 2000, which is before the first statewide Florida Building Code arrived in 2002.
Those original openings were never sized for today's design pressures. Each new unit has to meet current HVHZ testing and be anchored exactly the way its approval says. Check framing and bucks when you measure, not on install day.
| Decade built | Approx. units | Share of homes |
|---|---|---|
| 1970s | 9,458 | 20.0% |
| 1980s | 15,060 | 31.8% |
| 1990s | 10,063 | 21.3% |
| 2000-2009 | 9,118 | 19.3% |
| 2010 or later | 1,028 | 2.2% |
Four checks to make before anyone measures
- Confirm the city. Coral Springs ZIP codes include 33065, 33067, 33071, 33073, 33075, 33076 and 33077, but your permit goes to Coral Springs only if the address is inside city limits. Neighbors like Parkland, Margate and Tamarac have their own offices.
- Ask your association. Coral Springs is known for strict appearance rules from its planned-city roots, covering things like paint colors and roofing. Turtle Run, for example, is a single-family HOA community, and Eagle Trace includes the gated Fairways at Eagle Trace. Get the written window rules before you choose a product.
- Know your building type. A detached house or a townhouse under 30 feet follows one set of retrofit rules. Condo units follow different rules (see below).
- Check flood information if you are changing doors or openings near grade. The city's Engineering Department (954-345-2160) answers a Flood Information Request Form with your FIRM panel, flood zone and base flood elevation.
Measure and label each opening the way the city's packet asks
Coral Springs publishes its own Retrofit of Windows & Doors Submittal Packet, Form 015.1 (revised February 20, 2025). Measure with it in mind.
- Draw a simple floor plan in ink. Mark every window and door you plan to replace and give each a letter or number. That ID follows the opening through the permit.
- Record width, height and area. The Broward County Uniform Retrofit Window & Door Schedule asks for each opening's width, height and area. Measure the rough opening, not just the old glass.
- Note where each opening sits on the wall. The schedule splits walls into Zone 4 (interior of the wall) and Zone 5 (near the corners and ends). Corner openings carry higher pressures, so mark them.
- Label stacked glass from the bottom up. If one opening has glass stacked vertically, label it bottom to top: A, A1, A2.
- Flag shutters and mullions. Write down whether the opening has existing shutters and whether a new mullion tube will be needed between joined units.
Choose a product whose approval covers that exact opening
In the HVHZ, windows and doors up to 30 feet high must pass large-missile testing under TAS 201 and TAS 203. A 9-pound 2×4 is fired at the glass at 50 feet per second, then the unit goes through cyclic pressure loading. Broward's design wind speed for a typical home (Risk Category II) is 170 mph.
For every product, the permit packet asks for its NOA (Notice of Acceptance) or product approval. Highlight the sizes and pressures that match your openings and write the opening ID in each column.
Next comes the required design pressure. Broward's Formal Interpretation #24 allows three ways to show it for a house or townhouse under 30 feet: a signed and sealed site-specific plan from a Florida engineer or architect; an unsealed site plan plus a sealed worst-case pressure chart; or an unsealed site plan using the Broward County Fenestration Voluntary Wind Load Chart. The product's rated pressure must meet the required pressure for that opening.
If the buck or fasteners have to differ from what the NOA shows, FI #24 allows it only with a signed and sealed letter or drawing from a Florida engineer or architect.
| Mean roof height | Positive (psf) | Zone 4 wall interior (psf) | Zone 5 wall corner (psf) |
|---|---|---|---|
| 15 ft | +38.1 | -41.4 | -51.0 |
| 30 ft | +43.9 | -47.6 | -58.8 |
The Coral Springs permit, start to finish
The city's storm-recovery permitting guide lists non-like-for-like window and door replacement as work that needs a permit. The only related item it lists as not needing one is replacing glass in existing approved frames with no frame damage.
- Set up eTRAKiT access. Permits are handled at etrakit.coralsprings.gov. Anyone can search permit records without an account. A Public Account is needed to apply as an owner-builder, pay fees and schedule inspections. Contractors use a contractor login.
- Assemble the Form 015.1 packet. Include the labeled floor plan, highlighted NOAs, the Broward County Uniform Building Permit Application and the retrofit schedule. Altered openings need a sealed engineer or architect detail.
- Read FI #24 before you submit. Form 015.1 tells applicants to review Broward BORA Formal Interpretation #24 under the 8th Edition code. It sets the three accepted ways to document design pressure.
- Owner-builders sign the affidavit. If the owner is pulling the permit, Coral Springs requires its Owner/Builder Affidavit Packet (Form 029.0), signed by the owner with identity verification, before the permit is issued.
- Upload sealed documents online. Digitally signed and sealed documents must go through eTRAKiT. Walk-in paper submittals need two sets of plans, approvals and schedule. In-person service is at the One-Stop Shop at City Hall, 9500 West Sample Road.
- Record the Notice of Commencement. When the contract is above the threshold in Florida Statute 713.135, a recorded Notice of Commencement must be filed and posted on site before the first inspection.
- Pay the city's fees. Fees follow the Building Department's published user fee schedule and are paid through eTRAKiT.
Installation day and inspections under the 2025 rules
Materials typically arrive 2–3 weeks after contract for in-stock projects. Keep the permit card and the recorded Notice of Commencement posted on site.
Since February 1, 2025, the Coral Springs Building Department no longer gives set inspection times or books inspections by phone. Inspections are scheduled and tracked in eTRAKiT. Structural inspections get a two-hour window, so plan to have the house open for it.
If you need to cancel, call 954-344-1025 by 8 a.m. on the inspection day, or a re-inspection fee may apply.
- Each unit matches the NOA listed for its opening ID on the schedule.
- Anchors, bucks and mullions match the approval or the sealed engineer letter.
- Corner (Zone 5) openings carry products rated for the higher corner pressure.
- The Notice of Commencement is posted.
After the final inspection: close it out and document it
The job is not complete until the permit shows a passed final in eTRAKiT. Because records are public, you can search the address yourself and confirm the status.
Then book a wind mitigation inspection. The form, OIR-B1-1802, records the opening protection on your home so you can send it to your insurer. Keep the final permit and NOAs handy for the inspector.
Condos and townhouses in Coral Springs
About 27% of Coral Springs housing units are in buildings with five or more units, and about 9% are townhouses.
FI #24 covers detached one- and two-family homes and townhouses with a common roof height under 30 feet. Above 30 feet, generic pressure charts are not accepted, and a sealed site-specific design is required.
Condo boards are also dealing with safety inspections. Under Broward's Building Safety Inspection Program (BORA Policy #05-05, effective August 9, 2024), buildings are inspected at 25 years from the certificate of occupancy and every 10 years after. One- to four-family dwellings of three or fewer stories, fee simple townhouses and buildings under 3,500 sq ft are exempt. Ask your association what window product it specifies before you order.
What changes the cost of a Coral Springs project
For product prices, see the Windows Stock Market Coral Springs price page at windowsstockmarket.com/impact-window-prices-coral-springs-fl.
- Number and size of openings, especially tall windows and multi-panel sliding doors.
- Corner openings and taller homes that need higher-pressure products.
- Engineering: a sealed site-specific plan, a sealed buck or fastener letter, or a detail for altered openings.
- Association specs for frame color, tint or grids.
- City permit fees from the published schedule.
Getting help with a Coral Springs replacement
Vieser Construction is an authorized installer for ESW, Mr. Glass and PGT. We coordinate your complete installation from measurement to final inspection.
Permit assistance is available. Our team coordinates the complete permitting process, including required documentation, engineering and permit submission, when applicable.
Call or text (754) 707-3281 with your Coral Springs address, association name and list of openings.
Coral Springs window replacement questions
Do I need a permit to replace windows in Coral Springs?
Yes, in most cases. The city's permitting guide lists non-like-for-like window and door replacement as permitted work, and the city publishes Form 015.1 for retrofit windows and doors. Replacing only the glass in existing approved frames with no frame damage is listed as not needing a permit.
Coral Springs is far from the ocean. Do I still need HVHZ windows?
Yes. The Florida Building Code defines the High Velocity Hurricane Zone as Broward and Dade counties, so every Coral Springs address is in it. Products used up to 30 feet high must pass large-missile testing under TAS 201 and TAS 203, and a typical home is designed for 170 mph winds.
How do I schedule a window inspection in Coral Springs?
Online in eTRAKiT. Since February 1, 2025, the Building Department no longer books inspections by phone or gives set times. Structural inspections get a two-hour window. To cancel, call 954-344-1025 by 8 a.m. on the inspection day to avoid a possible re-inspection fee.
What is Form 015.1 and what goes in it?
It is Coral Springs' Retrofit of Windows & Doors Submittal Packet. It asks for an ink floor plan with every opening labeled, highlighted NOAs or product approvals, the Broward County Uniform Building Permit Application and retrofit schedule, a sealed detail for any altered opening, and the owner-builder affidavit if it applies.
Can I pull the window permit myself as the homeowner?
Coral Springs allows owner-builder permits, but the owner must complete and sign the Owner/Builder Affidavit Packet (Form 029.0) with identity verification before the permit is issued. A Public Account in eTRAKiT is needed to apply, pay fees and schedule inspections.
Can someone help with the Coral Springs permit paperwork?
Yes. Permit coordination is available for qualifying projects. Our team manages the required documentation, engineering coordination and submission process from start to finish.
Related
Replacing windows in Coral Springs? We coordinate your complete installation from measurement to final inspection.
Call (754) 707-3281 or request an estimate.
Sources: City of Coral Springs Building Department · City of Coral Springs eTRAKiT portal · City of Coral Springs Form 015.1 Retrofit of Windows & Doors Submittal Packet · City of Coral Springs Owner/Builder Affidavit Packet (Form 029.0) · City of Coral Springs Hurricane and Tropical Storm Recovery Permitting Guide · City of Coral Springs Flood Zone Information · Broward BORA Formal Interpretation #24 (8th Edition) and Voluntary Wind Load Chart · Broward BORA Policy #05-05, Building Safety Inspection Program · 2023 Florida Building Code excerpts (National Glass Association handout) · Florida Statutes s. 553.842 (product approval) · Florida Statutes s. 713.135 (Notice of Commencement) · U.S. Census Bureau ACS 2024 1-year (via Census Reporter) · Wikipedia: Coral Springs, Florida · Deseret News / AP, Wilma's wrath (Oct 25, 2005) · Eagle Eye, Broward recovers from impact of Hurricane Irma · BEX Realty: Turtle Run, Coral Springs
Related pages
Impact windows in Coral Springs: local rules and installation